Level measurement of DOP plasticizer in a tank

Application Report | Chemical

  • Storing organic raw material for delivery purposes in supply tanks
  • Monitoring the volume of an agitated medium with Guided Radar (TDR) technology
  • Installation in a high temperature (HT) environment of an ATEX Zone 2

Background

The Czech chemical company DEZA a. s. produces various raw materials for the construction and automotive industry. One of these organic compounds is dioctyl phthalate (DOP), a softening agent (plasticizer) widely used in the production of imitation leather or mould plastic.

In order to ensure the highest possible quality of the plasticizer, the raw material is always separated from its secondary components fi rst and then fi lled into a tank for delivery purposes. As a back-up for that tank, DEZA uses various supply tanks. If these tanks run empty, the whole delivery process comes to a standstill. Therefore, it is important for DEZA to monitor the volume in the tanks.

Measurement requirements

Over the past three years DEZA has tried to master this application using a radar sensor from a competitor. However, this level meter was unable to produce stable and reliable measuring values. It was particularly sensitive to disturbances in the pre-installed stilling well. For this reason the customer decided to test an alternative measuring principle in one of its supply tanks. This instrument was to fi t well into the existing infrastructure of the stilling well and had to be able to meet the challenging measurement environment of the application, particularly the agitator at the bottom of the supply tank.

Given that the DOP plasticizer is easily fl ammable, DEZA also required the level meter to be ATEX Ex d-approved.

Medium: Dioctyl phthalate (DOP)
Range:
(Level)
(Volume)

0.8…3.8 m / 2.6…12.5 ft
0…23 m3 / 0…812 ft3
Temperature: 160…180 °C / 320…356 °F
Tmax: 200 °C / 392 °F
Pressure: 0.5 barg / 7.2 psig

KROHNE Solution

All requirements of this application were met by the Guided Radar (TDR) level meter OPTIFLEX 2200. The device was delivered as a high temperature (HT) version and fitted on the tank roof with a flange connection. The housing of the OPTIFLEX 2200 was mounted horizontally to make the display screen easier to read. The Ø2 mm / 0.08" single cable probe of the level meter was installed into the existing 4.05 m / 13.3 ft long stilling well (Ø 36 mm / 1.4"). The cable probe of the OPTIFLEX 2200 has a counterweight with a stainless steel centering piece screwed into it. There was approx. 0.5 m / 1.6 ft of space underneath the stilling well leaving some clearance for the agitator.

The TDR (Time Domain Reflectometry) technology of the OPTIFLEX 2200 allows the device to measure level independently of physical property variations such as pressure changes. The measuring values are transmitted via a current output (4…20 mA) to a control room, where the DOP stored in the tank is permanently monitored.

Customer benefits

with the help of optiflex 2200 DEZA can continuously monitor level and volume in supply tank. stable relevant values provided by meter ensure customer is always aware amount dop that still be filled into final this enables company to avoid delivery issues.

Unlike the competitor devices, the KROHNE level meter with its integrated DPR algorithm is able to eliminate dynamically false reflections caused by environmental disturbances. Therefore, it was not needed to rebuild the tank, despite obstacles such as the agitator. The Guided Radar (TDR) fits best with the pre-installed stilling well environment. Commissioning and installing the device was a simple process. It was not necessary to empty the tank. Only the length of the probe had to be adapted and a quick configuration was carried out using PACTware™.

DEZA is very satisfied with the performance of the OPTIFLEX 2200. Having already had positive experiences with other KROHNE meters, the customer once again benefitted from the technical support of the local KROHNE sales engineers.

Products used

OPTIFLEX 2200

Guided radar (TDR) level transmitter for storage and process applications

  • Continuous measurement of level, distance, volume, mass or dielectric constant
  • Measuring range: 0.6…40 m / 2…131 ft (liquids), 0.6…20 m / 2…65.5 ft (solids)
  • -50…+300°C / -58…+572°F; -1…40 barg / -14.5…580 psig