Process Analysis – TSS 1050 | 2050 | 3050 | 4050 Hygienic turbidity meter

Hygienic turbidity meter for the food and beverage industry

TS 1050 | 2050 | 3050 | 4050 Hygienic turbidity meter
  • Compact, hygienic design with integrated electronics and parametrisation display
  • Elastomer-free sealing with an ingress protection of IP69K in a robust housing
  • Fast reacting and comprehensive process monitoring

The OPTISYS TSS x050 series are 180° absorption measurement systems for fluids and operate in the near infrared range (880 nm wavelength). The systems are installed in and/or on tanks or pipelines. The optical part of the systems are submerged in the process medium in order to measure the physical medium properties of absorbing light.

The TSS 1050 and TSS 2050 are simple designed, low cost measuring systems with a scale between 0 to 100%. There are 3 OPLs (Optical Path Length) available:

  • 5 mm / 0.2"
  • 10 mm / 0.5"
  • 20 mm / 0.8"

each for a different turbidity range. The TSS 2050 additionally is used in manual (RET) or automatic (RAM) operated retractable assemblies of the SENSOFIT family. There are only 2 OPLs available for the TSS 2050: 5 mm and 10 mm / 0.2" and 0.5".

The NIR measuring systems TSS 3050 and TSS 4050 are used for monitoring the optical density (extinction) or absorption of fluids in order to monitor the process results continuously or to securely indicate changes. A logarithmic amplifier guarantees a very wide measuring range, which is about 4 times the size of the TSS 1050 / 2050. The TSS 4050 additionally is used in manual (RET) or automatic (RAM) operated retractable assemblies of the SENSOFIT family.

Highlights

  • 180° transmitted light method according to ISO 7027
  • Measuring range (TSS 1050 / TSS 2050): absorbtion scale between 0 to 100% with 3 OPLs
  • Measuring range (TSS 3050 / TSS 4050): 0…6 OD, 0...3 AU, 0…3250 EBC,
    0…13000 FAU, 0…13000 TEF or 0…26.650 mg/l
  • Analogue output to provide measuring results
  • Digital output for setable switching points for enabling / disabling pumps, valves, etc.
  • Hygienic design due to bordered sapphire-glass, conus sealing (without any gaskets) and stainless steel (AISI 316L)
  • Robust housing with ingress protection of IP69K
  • Compact design with integrated electronics (no transmitter necessary)
  • Parametrisation via display or PC / Laptop

Industries

  • Food & Beverages
  • Breweries
  • Dairies
  • Process industry
  • Water supplier

Applications

  • Monitoring of water qualities
  • Detection of leakages
  • Optimizing of cleaning processes (CIP / SIP)
  • Filter monitoring (back washing, performance, etc.)
  • Optimising of separating processes (inlet / outlet)
  • Phase separation
  • Concentration measurement

TSS 1050

Hygienic turbidity meter TS 1050

 

Connection: G1/2 thread

Measuring range OPL 5 mm / 0.2":
0...500 EBC / 0…2000 FAU / 5.0 g/l ~ 0.4% TSS*

Measuring range OPL 10 mm / 0.5":
0...250 EBC / 0…1000 FAU / 2.5 g/l ~ 0.2% TSS*

Measuring range OPL 20 mm / 0.8":
0...100 EBC / 0…400 FAU / 1.0 g/l ~ 0.1% TSS*

TSS 2050

Hygienic turbidity meter TS 2050

 

Connection: PG 13.5 for retractable assemblies

Measuring range OPL 5 mm / 0.2":
0...500 EBC / 0…2000 FAU / 5.0 g/l ~ 0.4% TSS*

Measuring range OPL 10 mm / 0.5":
0...250 EBC / 0…1000 FAU / 2.5 g/l ~ 0.2% TSS*

 

* the values represent about 80% of the display scale

TSS 3050

Hygienic turbidity meter TS 3050

 

Connection: G1/2 thread

Measuring range OPL 5 mm / 0.2":
0...3 AU, 0…6 OD, 0…13000 FAU, 0…13000 FTU, 0…3250 EBC,
0…26.65 mg/l

TSS 4050

Hygienic turbidity meter TS 4050

 

Connection: PG 13.5 for retractable assemblies

Measuring range OPL 5 mm / 0.2":
0...3 AU, 0…6 OD, 0…13000 FAU, 0…13000 FTU, 0…3250 EBC,
0…26.65 mg/