DOUBLE ROD SINGLE ROD SINGLE ROD (SEGMENTED) COAXIAL COAXIAL (SEGMENTED) DOUBLE CABLE SINGLE CABLE 08 MM / 0.3 SINGLE CABLE 04 MM / 0.15 SINGLE CABLE 02 MM / 0.08
DOUBLE ROD SINGLE ROD SINGLE ROD (SEGMENTED) COAXIAL COAXIAL (SEGMENTED) DOUBLE CABLE SINGLE CABLE 08 MM / 0.3 SINGLE CABLE 04 MM / 0.15 SINGLE CABLE 02 MM / 0.08
MAXIMUM PROBE LENGTH, L
4m/13ft checked checked
6m/20ft checked checked checked
8m/26ft checked
35m/115ft checked checked checked
LIQUIDS
Liquid application checked checked checked checked checked checked checked checked
LPG, LNG checked checked checked checked partially1 partially1
Highly viscous liquids checked checked checked checked
Highly crystallising liquids checked checked checked checked
Highly corrosive liquids checked checked checked checked checked checked checked
Foam checked checked checked checked checked checked
Agitated liquids checked partially2 partially2 checked checked partially2 partially2 partially2
High-pressure applications partially3 partially3 partially3 partially3 partially3 partially3 partially3 partially4
High-temperature applications partially5
Spray in tank partially1 partially1 checked checked partially1 partially1
Storage tanks checked checked checked checked checked checked checked checked
Installation in bypass chamber checked checked checked checked checked checked
Small diameter nozzles checked checked checked checked
Long nozzles checked checked checked checked
Stilling wells checked checked checked checked checked checked checked checked
Interface measurement checked checked checked checked partially6 partially6
SOLIDS
Powders checked checked checked partially7
Granules, <5mm/0.1" checked partially7
checked Suitable
checked Install the device in a stilling well or a bypass chamber
checked Use this probe with an anchor fitting. For more data, refer to the handbook.
checked Max. pressure is 100 bar / 1450 psig. Refer to the pressure-temperature table for probe selection.
checked Optional. Max. pressure is 300 bar / 4350 psig. Refer to the pressure-temperature table for probe selection.
checked Optional. Max. temperature is 300°C / 570°F. Refer to the pressure-temperature table for probe selection.
checked Max. length is 20 m / 65.5 ft, more on request
checked Max. length is 10 m / 33 ft, more on request