SENSOFIT INS 1310

Insertion assembly for all-purpose applications in various industries

  • For use with Ø12 / 120 mm or Ø0.47 / 4.7" sensors
  • Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
  • Insertion length: 70 mm / 2.75"
  • Max. +140°C / +284°F and 10 bar / 145 psi

SENSOFIT INS 1310

Insertion assembly for all-purpose applications in various industries

  • For use with Ø12 / 120 mm or Ø0.47 / 4.7" sensors
  • Sensor connection: PG13.5; Process connection: INGOLD G1¼ (coupling nut)
  • Insertion length: 70 mm / 2.75"
  • Max. +140°C / +284°F and 10 bar / 145 psi

Overview

The SENSOFIT INS 1310 is a static insertion assembly for all-purpose applications in various industries. Its stainless steel (1.4404 / 316L) construction with Ra <0.8 is also made for use in hygienic environments. The housing is suitable for all Ø12 / 120 mm or Ø0.47 / 4.7″ sensors with sensor connection PG13.5. It comes with INGOLD connection (G114 coupling nut with 28 mm / 1.1″ O-ring position) to be installed into tanks and pipes.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Sealings: EPDM (incl. FDA/USP VI certificate) or FPM
  • Surface finish Ra<0.8
  • Material: Stainless steel (1.4404 / 316L)
  • Protection cap for cable connection
  • Optional sensor protection cage
Related products
SMARTPAT PH 8150
Potentiometric pH sensor for chemicals and industrial wastewater applications
  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with open diaphragms and Pt1000 for temperature compensation
SMARTPAT PH 8320
Potentiometric pH sensor for water and wastewater applications
  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and Pt1000 for temperature compensation
SMARTPAT PH 8530
Potentiometric pH sensor for pure water and low conductivity media (>2 μS/cm)
  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +80°C / +176°F; 12 bar / 174 psi
  • Glass sensor with 3 ceramic diaphragms and Pt1000 for temperature compensation
SMARTPAT PH 8570
Potentiometric pH sensor for food, beverage and pharmaceutical applications
  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • 0…14 pH; Max. +140°C / +284°F (SIP/CIP); 12 bar / 174 psi
  • Autoclavable glass sensor with ceramic diaphragm and Pt1000 for temperature compensation
SMARTPAT ORP 8150
Potentiometric ORP sensor for chemicals and industrial wastewater applications
  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +130°C / +266°F; 12 bar / 174 psi
  • Glass sensor with platinum electrode, open diaphragm and Pt1000 temperature sensor
SMARTPAT ORP 8510
Potentiometric ORP sensor for water and wastewater applications
  • 2-wire loop powered, 4…20 mA/HART® 7, for direct connection to a PCS
  • Process connection: PG13.5
  • -1500…+1500 mV; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with platinum electrode, ceramic diaphragm and Pt1000 temperature sensor
OPTISENS PH 8100
Potentiometric pH sensor for chemicals, industrial wastewater and low conductivity media (>2 μS/cm)
  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +130°C / +266°F; 10 bar / 145 psi
  • Glass sensor with 2 open diaphragms and Pt100 for temperature compensation
OPTISENS PH 8300
Potentiometric pH sensor for wastewater, surface and process water applications
  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 10 bar / 145 psi
  • Glass sensor with PTFE diaphragm and optional Pt100 for temperature compensation
OPTISENS PH 8500
Potentiometric pH sensor for potable water applications
  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +70°C / +158°F; 2 bar / 30 psi
  • Glass sensor with ceramic diaphragm and optional Pt100 for temperature compensation
OPTISENS PH 9100
Potentiometric pH sensor for lower conductivity water applications (>20 μS/cm)
  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with open glass sleeve diaphragm
OPTISENS PH 9500
Potentiometric pH sensor for lower conductivity water applications (>50 μS/cm)
  • For use with analytical transmitter
  • Process connection: PG13.5
  • 0…14 pH; Max. +100°C / +212°F ; 1 bar / 14 psi
  • Liquid electrolyte glass sensor with 3 ceramic diaphragms
SENSOFIT MOUNT 1000
Mounting assembly for applications in various industries
  • For use with retractable or insertion assemblies into pipes and tanks
  • Assembly connection: G1¼ (male); Process connection: Socket weld
  • Straight or inclined version
  • Max. +140°C / +284°F and 16 bar / 232 psi
Email