Equipping a mixing facility for edible oil with measurement technology

Application Report | Food & Beverage

  • More accurate dosing of edible oils
  • Traceability of product and energy consumption
  • All instrumentation from one provider
  • Technical support starting with project planning right through to after-sales care

Background

Lesieur is a French food company founded in 1908. It is now a major player in the production and marketing of edible oils and sauces. Lesieur is a subsidiary of Avril, a financial and industrial business in the oil and protein sector, and sells the products under the same brand name.

The company has built a new packaging and bottling plant for vegetable oils (rapeseed and sunflower oil) at its Bassens location. This plant, in conjunction with the edible oil refinery of Saipol (another subsidiary of Avril) produces 100 million litres of edible oil per year, in 100 different grades.

Measurement requirements

In terms of technology, the goal was to increase the processing capacity of the 100 different types compared to the old facility. Production of the individual mixtures had to take place with maximum accuracy and taking into account the largest possible measuring range. The entire instrumentation had to comply with the standards of the food and beverage industry (EC1935/2004). The customer took on the project management from start to finish but the project planning, procurement and execution was shared by several different locations in France. Consequently, there were different expectations linked to the project.

When it came to technical project planning, the focus was on measuring technology, particularly measuring accuracy. In terms of purchasing, the main focus was on reducing the number of suppliers as well as costs. The production department placed particular importance on service and the user-friendliness of the instrumentation.

KROHNE Solution

At first competitors bid on this project. KROHNE measurement technology had never been used in the old facility. The customer then learned of the simple and reasonably priced OPTISWITCH 6600 level switch. KROHNE was able to bring its knowledge of instrumentation to the project by providing the appropriate measuring devices for all of the necessary measurements in process and utility applications as well as relevant audits and training sessions.

177 measuring devices for pressure, temperature, level and flow were delivered for this facility. One of the project's focal points was the 15 Coriolis mass flowmeters for the three mixing stations into which the raw edible oil from the adjacent production facility was dosed. This allows the customer to provide greater variety of edible oils.

KROHNE was able to set itself apart from the competition when it came to the following points:

  • Pre-sales services (design, consultation, project coordination) and customer service (installation verification, commissioning and training)
  • As a full-service provider, KROHNE was able to provide all of the instrumentation for pressure, temperature, level and flow
  • Good price/performance ratio

Customer benefits

According to the technical director at Lesieur, the company assessed suppliers based on the total cost of ownership, taking into account both the operating costs and purchasing costs. The customer was able to reach his objectives in terms of dosing accuracy for the edible oils, accurately tracking consumption in order to minimise waste and monitor process-related energy consumption. In addition, the customer took advantage of service and training sessions that allow him to independently check device performance.

Products used

OPTIMASS 6400

Coriolis mass flowmeter for advanced process applications

  • High accuracy (±0.05% flat), for cryogenic to high temperature media (-200…+400°C / -328…+752°F); maintains operation over a wide range of gas fractions and complex flow conditions (EGMTM)
  • SIL 2/3; CT: OIML R117, R137, MI-005, MI-002; API, AGA; hygienic certifications
  • Flange: DN10…300 / ½…12", max. PN 160 / ASME Cl 1500
  • 3 x 4…20 mA, HART®7, Modbus, FF, Profibus-PA/DP, PROFINET, EtherNet/IP™, Bluetooth®

H250 M40

Variable area flowmeter for liquids and gases

  • Modular design: from mechanical indicator to 4…20 mA/HART®7, FF, Profibus-PA and totalizer
  • Any installation position: vertical, horizontal or in fall pipes
  • Flange: DN15…150 / ½…6"; also NPT, G, hygienic connections, etc.
  • -196…+400°C / -320…+752°F; max. 1000 barg / 14500 psig

OPTISWITCH 6600

Capacitance level switch for hygienic and industrial applications

  • Point level detection of solids, liquids and liquid-liquid interface
  • Wide variety of hygienic process connections available
  • -20…+200°C / -4…+392°F; -1…16 barg / -14.5…580 psig

OPTIBAR P 1010

Pressure transmitter for basic pressure and level applications

  • Ultra-compact design with recessed stainless steel diaphragm
  • Up to 600 bar / 8700 psi
  • Thread: ¼, ½ NPT (male); G¼, G½ (male)
  • 2-wire 4…20 mA

OPTITEMP TRA-S11

Resistance (RTD) temperature assembly for lower temperature applications

  • Thread connection
  • DIN-style based on form 8, welded multipart thermowell with straight tip
  • -40…+150°C / +302°F

OPTIMASS 1300

Coriolis mass flowmeter for universal applications and process control

  • For mass, density and volume flow of liquids and gases up to +130°C / +266°F
  • Also certified for hygienic use
  • Flange: DN15…100 / ½…4", max. PN100 / ASME Cl 600; many hygienic fittings
  • 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP