Wedge meter

Engineered primary element for DP flow measurement of high viscous and solids-containing fluids

  • Meter run with integrated V-shaped wedge
  • For slurry and fibrous liquids containing solids or gases
  • Reynolds number down to 300
  • Applicable for bi-directional measurement

Wedge meter

Engineered primary element for DP flow measurement of high viscous and solids-containing fluids

  • Meter run with integrated V-shaped wedge
  • For slurry and fibrous liquids containing solids or gases
  • Reynolds number down to 300
  • Applicable for bi-directional measurement

Overview

A wedge meter is an engineered primary flow element for extremely challenging applications. Due to its robust design and possibility for direct attachment of a diaphragm seal assembly, the primary element is also perfectly suited for differential pressure flow measurements of erosive, abrasive and solids-containing fluids without the risk of clogging.

  • Low maintenance due to robust design
  • Long service life, low wear
  • For highly viscous and particle-laden fluids
  • Low risk of clogging
Related products
0 / 0
Wedge flowmeter
DP flowmeter for harsh process applications with abrasive and viscous media
  • Rugged design, suitable for abrasive/solids-containing fluids and high viscosities (ferromagnetic slurries, coker feed, ADU/VDU residues, etc.)
  • Up to +500°C / +932°F; max. 160 bar / 2320 psi line pressure (others on request)
  • Flange: DN50…600 / 2…24" (others on request)
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA
OPTIBAR DP 3050
Differential pressure transmitter for general flow, level and differential pressure applications
  • The most compact design in its class
  • Measuring ranges: 100 mbar…16 bar / 1.45…232 psi; Line pressure: up to 160 bar / 2320 psi
  • Reference accuracy ± 0.1%
  • 2-wire, 4…20 mA/HART®7
OPTIBAR DP 7060
Differential pressure transmitter for flow, level, differential pressure, density and interface measurements
  • High performance DP transmitter with integrated line pressure measurement
  • Measuring range: 30 mbar…16bar / 0.44…232 psi; Line pressure: up to 400 bar / 5800 psi
  • Reference accuracy of ±0.065%
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®
Email
Contact