Wedge flowmeter

DP flowmeter for harsh process applications with abrasive and viscous media

  • Rugged design, suitable for abrasive/solids-containing fluids and high viscosities (ferromagnetic slurries, coker feed, ADU/VDU residues, etc.)
  • Up to +500°C / +932°F; max. 160 bar / 2320 psi line pressure (others on request)
  • Flange: DN50…600 / 2…24" (others on request)
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

Wedge flowmeter

DP flowmeter for harsh process applications with abrasive and viscous media

  • Rugged design, suitable for abrasive/solids-containing fluids and high viscosities (ferromagnetic slurries, coker feed, ADU/VDU residues, etc.)
  • Up to +500°C / +932°F; max. 160 bar / 2320 psi line pressure (others on request)
  • Flange: DN50…600 / 2…24" (others on request)
  • 2-wire 4…20 mA/HART®, FF, Profibus-PA

Overview

The wedge flowmeter is designed for difficult applications where other flow technologies fail or have a very limited-service life. It can cope with high viscosities, abrasive solids-containing fluids or liquids with a tendency to scaling or agglomeration. The materials can pass the wedge restriction where other flow devices lead to material build-up in a kind of "damming" effect. Due to these advantages the wedge flowmeter has been established as a standard device in particularly difficult applications with harsh process conditions such as refineries where solid coke can pass the flowmeter along with the hot feed flow or in oil production and mining where solids are not yet separated from the stream.

Product features and options depend on device configuration: Contact us to make sure that your preferred functionality can be combined in one device.

  • Engineered assembly suitable for harsh flow applications with high viscosities, abrasive fluids and fluids containing solids
  • Solid materials or agglomerations can pass the flow restriction
  • Bi-directional flow measurement capabilities, no moving parts
  • Redundant versions available (1oo2, 2oo3)
  • Large choice of wetted materials for meter body and diaphragm seals
  • Manufacturing and calibration capabilities up to 48"
  • Reduced TCO due to reduced need for recalibration in the field through advanced 3-D linearised OPTIBAR DP transmitters
  • Complete flowmeter solution with wedge element, DP transmitter with diaphragm seals, flow computer, accessories, engineering, testing and documentation from a single source
  • HART®7, Foundation fieldbus and Profibus-PA communication options
  • SIL 2/3 certified versions
  • Ex ia, Ex d approvals
  • International references with renowned EPCs

Related products

OPTICHECK Pressure Mobile

Mobile app for pressure transmitters

  • Works with all OPTIBAR PM 5060, OPTIBAR PC 5060 and OPTIBAR DP 7060 equipped with Bluetooth display and adjustment module
  • Wireless device commissioning, verification and monitoring even in hard-to-reach areas
  • Parameterisation similar to PACTware DTM including remote SIL mode activation
  • Free download for iOS and Android

OPTIBAR FC 1000

Flow computer for process control of liquids, gases and steam

  • High performance flow and energy calculation with DP flow elements, volumetric or mass flowmeters
  • Compact design, quick and easy-to-operate via TFT touch screen
  • Enables split-range operation with two pressure transmitters for increased measuring dynamics
  • HART® communication with all common DP transmitters for loss-free measured data transmission and possibility of automatic zero point adjustment

OPTIBAR DP 3050

Differential pressure transmitter for general flow, level and differential pressure applications

  • The most compact design in its class
  • Measuring ranges: 100 mbar…16 bar / 1.45…232 psi; Line pressure: up to 160 bar / 2320 psi
  • Reference accuracy ± 0.1%
  • 2-wire, 4…20 mA/HART®7

OPTIBAR DP 7060

Differential pressure transmitter for flow, level, differential pressure, density and interface measurements

  • High performance DP transmitter with integrated line pressure measurement
  • Measuring range: 30 mbar…16bar / 0.44…232 psi; Line pressure: up to 700 bar / 10,153 psi
  • Reference accuracy of ±0.065%
  • 2-wire, 4…20 mA/HART®, FF, Profibus-PA, Bluetooth®

OPTIBAR DSD 3100

Diaphragm seal with flange design and optional extension

  • Direct attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +150°C / +302°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3110

Diaphragm seal with flange design and optional extension

  • Capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3210

Diaphragm seal with flange design and optional extension

  • Direct and capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

OPTIBAR DSD 3220

Diaphragm seal with flange design and optional extension

  • 2 x capillary tube attachment to OPTIBAR DP 7060 differential pressure transmitter
  • Flange: DN50…100 / 2…4"; max. PN63 / ASME Cl 300
  • Up to +400°C / +752°F
  • Wetted materials for aggressive, corrosive, viscous, solidifying or abrasive media

Wedge meter

Engineered primary element for DP flow measurement of high viscous and solids-containing fluids

  • Meter run with integrated V-shaped wedge
  • For slurry and fibrous liquids containing solids or gases
  • Reynolds number down to 300
  • Applicable for bi-directional measurement